Gamlen CHE
Controlled Humidity Environment
Make and test tablets at the humidity your process runs at. A humidity generator and glove box in one, from 0 to 98% RH, in air or inert gas, on any lab bench.
- Proprietary humidity generator combined with a glove box
- Operates between 0 and 98% RH, controlled to ±0.7% RH
- Air or inert gas atmosphere for moisture- and oxygen-sensitive materials
- Needs only a dry air supply and AC power; portable, fast set-up
Quotes are prepared by a Gamlen scientist, not a sales desk. Typical reply within one working day. Worldwide shipping, installation and training available.
Overview
Humidity changes how a powder compacts
Humidity changes the compressibility of key pharmaceutical ingredients such as microcrystalline cellulose, so formulation and manufacturing teams need to understand its impact. Products that must stay dry or inert to remain stable, such as effervescent materials or those sensitive to oxygen or moisture, have to be studied under real manufacturing conditions.
The Gamlen CHE puts a proprietary humidity generator and a glove box together on the bench, so a D-Series and its tooling, balance and TTA can make and test tablets at any humidity from 0 to 98% RH, controlled to ±0.7%, in air or under an inert gas.
It supports dry granulation, milling, compaction and packing under low humidity, enabling quick, GMP-compliant manufacture of small batches, and it is equally suited to material characterisation, pre-formulation, formulation and process development, QbD and QC of incoming APIs and excipients. Tablets made in the CHE can be transferred to closed containers or used for long-term stability studies.
Applications
From a compressibility study at three humidities to a GMP batch of effervescent tablets, these are the jobs the CHE does.
Set. Stabilise. Make and test.
A controlled atmosphere on the bench in minutes, with no services beyond dry air and a power socket.

Set the humidity
Dial in any point from 0 to 98% RH. The proprietary generator holds it to ±0.7% RH and reports temperature to 0.1 °C; fill the easy-change water reservoir for high humidity, or switch to an inert gas feed.

Load the instrument
The D-Series, tooling, balance and TTA all fit inside the glove box, and the ergonomic curved access face keeps the operator comfortable through a full run.

Make and test
Compact, measure and break the tablets inside the controlled atmosphere, with every result captured by Dashboard NOVA as normal.
Dashboard NOVA ›
Data at process humidity
Compaction profiles that reflect the conditions the product will actually see, and tablets that can go straight into closed containers for stability work.
- Profiles at any RH
- Inert-gas option
- Tablets ready for stability
Why it works
What the CHE adds to a Gamlen bench.

A humidity generator and a glove box in one
Most humidity chambers are for storing samples. The CHE is for working in: a proprietary humidity generator feeds a glove box large enough for a D-Series and its accessories, so the whole make-and-test workflow happens at the set humidity rather than only the storage step.
- 0 to 98% RH, controlled to ±0.7%
- 0.1 °C temperature resolution
- Easy-change water reservoir
Air or inert gas
Switch the atmosphere to an inert gas for oxygen-sensitive APIs and effervescent formulations. Combined with low humidity, materials that would normally need a dedicated dry room can be developed and manufactured in small batches on an ordinary bench.
- Inert-gas operation
- Low-humidity dry granulation, milling and compaction
- GMP-compliant small-batch manufacture


Portable and quick to set up
The CHE needs only a dry air supply and AC power. It is easily portable, sets up fast and is simple to operate, so it can move between labs or be brought out for a specific study rather than occupying permanent space.
- Dry air and AC power only
- Fast set-up, simple operation
- Ergonomic curved access face
Specifications
At a glance
Full specification sheet available in the brochure. Ask us about configuration options and compliance packs.
| Humidity range | 0 to 98% RH |
|---|---|
| Humidity control | ±0.7% RH |
| Temperature resolution | 0.1 °C |
| Atmosphere | Air or inert gas |
| Services required | Dry air supply and AC power only |
| Configuration | Proprietary humidity generator plus glove box, easy-change water reservoir, ergonomic curved access face |
| Portability | Easily portable, fast set-up |
| Works with | Gamlen D-Series, TTA, GamPette, balance and micrometer inside the glove box |
Request a quote
Tell us what you want to measure
A scientist, not a sales desk, prepares every quote. Tell us the material and the problem and we will recommend the right configuration.
- 01You send a short brief (the quote form or a call).
- 02We recommend a configuration and send a written quote, usually within one working day.
- 03Optional demonstration on your own powder, remote or in our London lab.